Atkinson Dynamics AD-27 Especificações Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 15
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
-12-
Using Call Dry Contacts with AC
The dry contacts can be used to switch devices such as an auxiliary sound
or light when call is depressed. The maximum ratings for the dry contacts
 are.4amps@125VACand1.25amps@24VDC.Thismethodassuresa
call is received even when the volume on one of the intercoms is turned all
the way down.
Figure 7.
No Remote Power Available
 IntercomIsuppliestheDCpowertothesecondintercom.Earthground
must be wired on the second unit.
Figure 8.
290A3083B
24 VDC
GROUND
REMOTE
AUDIO +
AUDIO
-
DRY CONTACT
DRY CONTACT
24 VDC
GROUND
REMOTE
AUDIO +
AUDIO
-
DRY CONTACT
DRY CONTACT
NEUTRAL
HOT
EARTH GND.
NEUTRAL
HOT
EARTH GND.
INTERCOM I
AD-28LD-MV MASTER
J7
J2 J2
J7
INTERCOM II
AD-28LD-MV SLAVE
NO REMOTE POWER
AVAILABLE
1K
1 WATT
7
6
5
4
3
2
1
3
2
1
3
2
1
7
6
5
4
3
2
1
AC
Vista de página 11