Theintercomhousinghastwo1/2”-14IPSopeningsinthebottom.Wheninstallingtheconduit
to these openings, seal the threads with pipe compound or other sealing material.
For shipboard applications, installations shall be in accordance with the
UnitedStatesCoastGuard,Title46CRF,Parts110-113.
E. Electrical Connections.
Donotconnectwireswhenpowerisapplied.
Allwiringtotheintercomisterminatedtotheterminalblockprovided.Theterminalblock
plugs into a header on the PC board and is configured such that it can only plug in one way.
Figure6showstheorientationofthewiringblockanddescribesthefunctionofeachposition.
There is one jumper shown on the PC board in Figure 6 that may need to be moved depending
onthedesiredoperationoftheintercom.J2isforconguringtheintercomaseitheraMasteror
Slave device. The intercom is factory set in the Master position.
Thereisaswitchontheboardtoconguretheoperationoftheboardfrom120VACto
240VAC.Theswitchisfactorysetfortheintercomtooperateon120VAC(seeFigure6).
See figures 7 through 13 for typical intercom configurations.
TheModelAD-28X-MV’scircuitsarenotnonincendiveeldwiringcircuits
exceptforfootswitches.WireallcircuitsconnectedtotheAD-28X-MV
IntercomusingClassI,Division2wiringmethodsspeciedinArticle501-4
(b)oftheNEC.
F. Service.
Anymaintenancemustbeperformedbyatrainedelectricianinaccordance
with NEC guidelines and local codes.
1. General.
The call signal is substantially louder than normal voice messages being car
riedontheline.Donotdepressthecallswitchwhilecarryingonaconversa
tion with someone on the system. This will subject the listener to very loud
sound levels.
AtkinsonDynamicswillserviceyourequipmentorprovidetechnicalassistancewithany
problems that cannot be handled locally.
AnyunitsreturnedtoAtkinsonDynamicsforservice,inspection,orrepairmustbeac
companiedbyaReturnMaterialAuthorization.ThisR.M.Acanbeobtainedonlyfromthe
factorybycalling(888)751-1500.
Atthistimeabriefexplanationoftheservicerequestedorthenatureofthemalfunction,
should be given.